summaryrefslogtreecommitdiff
path: root/loragw_band_survey/README
diff options
context:
space:
mode:
Diffstat (limited to 'loragw_band_survey/README')
-rw-r--r--loragw_band_survey/README57
1 files changed, 0 insertions, 57 deletions
diff --git a/loragw_band_survey/README b/loragw_band_survey/README
deleted file mode 100644
index a34134d..0000000
--- a/loragw_band_survey/README
+++ /dev/null
@@ -1,57 +0,0 @@
- / _____) _ | |
- ( (____ _____ ____ _| |_ _____ ____| |__
- \____ \| ___ | (_ _) ___ |/ ___) _ \
- _____) ) ____| | | || |_| ____( (___| | | |
- (______/|_____)_|_|_| \__)_____)\____)_| |_|
- ©2013 Semtech-Cycleo
-
-Lora Gateway RF band survey application
-========================================
-
-1. Introduction
-----------------
-
-This software is used to scan the RF band and measure background RSSI and some
-measurement of interferer pattern.
-The RSSI is purposefully skew towards high values, to detect high power
-interferers (eg. a gateway installed in the beam of a powerful base station),
-and not to characterize the noise floor, or accurately measure the time-domain
-profile of interferers.
-
-2. Dependencies
-----------------
-
-This software call functions in the loragw_reg and loragw_reg sub-modules of
-loragwlib. loragw_spi is used indirectly, and the loragw_hal sub-module is not
-used at all, except for constants define at the top level.
-
-It has been qualified with the Lora Getway HAL library version 1.0.0, and should
-be compatible with any compatible later version that use the same API, or a
-downward-compatible one.
-
-Because some non-public functions from loragw_hal had to be re-implemented, any
-change in the IP might affect this program even if an updated Lora Getway HAL
-library is provided.
-Connecting an incompatible concentrator board should give you the error:
-"ERROR: fail to connect to concentrator board"
-
-3. Usage
----------
-
-To stop the application before the end of the measurement, press Ctrl+C.
-
-By default, the program scans the whole band (start and stop frequency defined in
-the loragw_hal.h file) with a 200 kHz measurement step.
-Use -f option to change start and stop frequency, and measurement step.
-
-The resolution bandwidth of the scan is 200 kHz and cannot be set by the user.
-
-The measurement results are put in a CSV file whose name include a UTC timestamp
-of measurement starting time in ISO 8601 recommended compact format:
-yyyymmddThhmmssZ (eg. 20131009T172345Z for October 9th, 2013 at 5:23:45PM UTC)
-
-4. Changelog
--------------
-
-2013-10-24, v1
-Initial version.